EonStor S12S-J1000-G 12 bays, 2U, SAS to SAS/SATA. JBOD, Single Control. - detail
Skupina | INFORTREND | |
---|---|---|
Kód | IF00062 | |
PartNo | ESS12SJ1000G-8B32 | |
Dostupnost | do 3-4 týdnů | |
Množství | ||
Cena bez DPH | 73 157 Kč | |
Cena s DPH | 88 520 Kč | |
Recyklační poplatek | bez DPH: 12 Kč; s DPH: 15 Kč; Počítačové servery všechny druhy vyjma sálových | |
Cena celk. | 88 535 Kč | |
Garance ceny | Nalezli jste jinde na internetu nižší cenu? Informujte nás! | |
Záruka | 36 Měsíce | |
Status | - V ceníku | |
Stránka výrobce | http://www.infortrend.com/uk/Products/Families/ES | |
Obrázek je pouze ilustrační |
Zařazení |
---|
Kategorie Disková pole Výrobci Infortrend |
Popis produktu |
---|
SAS JBOD subsystem, 2U 12-bay rack mount, single controller module. Two SAS ports (SFF-8470) for connecting RAID controller and chaining to the next SAS JBOD. SAS and SATA-II drives both supported. Use together with S12S-G1030 and S12S-G1033. Connecting directly to HBA/switch/hub are not supported. Redundant PSUs and redundant FANs with status LEDs (no LCD front panel). Expansion enclosure for SAS to SAS RAID systems SAS drives for high performance and high reliability SATA drives for low cost and high capacity applications Highest density, 12 drives in 2U rack space Redundant or single JBOD controllers Two (2) SAS 4x wide ports per controller Diagnostics LED panel Proprietary enclosure service via connections (in-band) with the managing RAID enclosure Path redundancy via separate SAS domains (S12S-J1002-R) Host-to-Drive Interface JBOD Model Corresponding RAID Subsystem(s) Configuration Form Factor Model Max. Connection SAS to SAS/SATA II S12S-J1000-G S12S-G1030 4 JBODs Single Expander Controller 2U rack-mount SAS to SAS/SATA II S12S-J1002-R S12S-R1032 3 JBODs Redundant Expander Controllers 2U rack-mount Specifications Host Interface Two (2) SAS 4x wide ports per controller. Proprietary enclosure service via in-band methodology Drive Interface Twelve (12) hot swappable SAS/SATA II disk drives System Components Redundant or single JBOD controller configurations Fault-tolerant modules interfaced through a common backplane Redundant, hot swappable 460W/530W power supply units Redundant, dual-speed cooling modules LED diagnostics panel Management Management of multiple enclosures via RAID firmware and/or through GUI Module status LED indicators: Six (6) on LED panel (1 service LED and 5 status LEDs) Two (2) per drive tray Three (3) per controller module (1 Ready/Failed LED and two (2) Link status LEDs) One (1) per power supply unit Two (2) per cooling module Physical/Electrical Interface Host Interface: Eight (8) SMP PHYs interfaced through two (2) SAS 4x wide ports per controller. Drive Interface: 3Gbps SAS/ SATA II Power Supply Module Specifications Power Consumption 460W/ 530W (J1000-G/J1002-R) Input Voltage 100VAC @ 8A/10A or 240VAC @ 4A/5A with PFC (auto-switching) Frequency 50 to 60Hz/ 47 to 63Hz Cooling Module Specifications Speed High or low rotation speed controlled by firmware Max. Air Flow (each module) J1000-G: 1.3 m3/min (high speed); 0.9 m3/min (low speed) J1002-R: 90CFM(high speed); 70.7CFM (low speed) Environmental Specifications Humidity Operating: 5% to 95% (non-condensing) Non-operating: 5% to 95% (non-condensing) Temperature Operating: 0° to 40°C (32°F to 104°F) Non-operating: -40° to 60°C (-40°F to 149°F) Altitude Operating: Sea level to 3048m (12,000 ft.) Non-operating: Sea level to 12,192m (40,000 ft.) Dimensions Dimensions With Forearm Handles Height 88mm Width 482mm Length 516mm / 522mm Package dimensions: 344/390(H) x 600/575(W) x 670/780(D) mm System weight Net Weight S12S-J1000-G 17.6 kg ( 38.80 pounds); S12S-J1002-R 15.7kg ( 34.61 pounds ) Gross Weight S12S-J1000-G 25.5 kg ( 56.22 pounds); S12S-J1002-R 23.6kg ( 52.03 pounds ) |